{"id":27530,"date":"2026-06-25T21:24:51","date_gmt":"2026-06-25T21:24:51","guid":{"rendered":"https:\/\/airtec.global\/?p=27530"},"modified":"2026-07-22T17:43:18","modified_gmt":"2026-07-22T17:43:18","slug":"iso-8573-4-isokinetic-sampling","status":"publish","type":"post","link":"https:\/\/airtec.global\/en\/2026\/06\/25\/iso-8573-4-isokinetic-sampling\/","title":{"rendered":"ISO 8573-4 and Isokinetic Sampling: The Critical Factor for Measuring Particles in Compressed Air"},"content":{"rendered":"<div class=\"exair-hero-block\" style=\"margin-bottom:24px;\">\n  <span class=\"exair-badge\">SUTO iTEC \u00b7 S600<\/span>\n  <h2 style=\"color:#fff;margin:8px 0;\">ISO 8573-4 and Isokinetic Sampling<\/h2>\n  <p style=\"color:#b0b0c0;margin:0;\">ISO 8573-4 isokinetic sampling is the critical factor that determines whether your compressed air quality measurements are accurate or misleading. Many audits fail not because of the instrument, but because of incorrect sampling conditions. Here&#8217;s why.<\/p><\/div>\n\n\n\n<div style=\"margin:24px 0;\">\n  <img decoding=\"async\" src=\"https:\/\/airtec.global\/wp-content\/uploads\/2026\/06\/WhatsApp-Image-2026-06-26-at-2.11.15-PM.jpeg\" alt=\"ISO 8573-4 isokinetic sampling SUTO iTEC S600 portable compressed air quality analyzer\" style=\"width:100%;max-width:600px;display:block;margin:0 auto;border-radius:8px;\" title=\"\">\n<\/div>\n\n\n\n<h2>What is ISO 8573 and Why Does It Matter?<\/h2>\n<p>ISO 8573 is the international standard used to classify compressed air quality. Its goal is to define the permitted levels of contaminants within an industrial compressed air system, mainly solid particles, moisture, and oil.<\/p>\n\n<div style=\"display:grid;grid-template-columns:1fr 1fr;gap:16px;margin:24px 0;\">\n  <div class=\"exair-content-block\">\n    <h3>ISO 8573-1: Purity Classification<\/h3>\n    <p>Establishes the purity classes of compressed air, defining maximum contamination limits permitted according to the industrial application. The pharmaceutical industry requires extremely low levels, while general applications may tolerate higher levels.<\/p>\n  <\/div>\n  <div class=\"exair-content-block\">\n    <h3>ISO 8573-4: Measurement Method<\/h3>\n    <p>While ISO 8573-1 defines the limits, ISO 8573-4 establishes <strong>how<\/strong> particle measurements must be performed: sampling techniques, counting methods, test conditions, and requirements for representative results.<\/p>\n  <\/div>\n<\/div>\n\n\n\n<div style=\"margin:24px 0;\">\n  <img decoding=\"async\" src=\"https:\/\/airtec.global\/wp-content\/uploads\/2026\/06\/Soruces-of-Contamination.png\" alt=\"Sources of contamination in compressed air systems ISO 8573\" style=\"width:100%;border-radius:8px;\" title=\"\">\n<\/div>\n\n\n\n<h2>What is Isokinetic Sampling?<\/h2>\n<p>Isokinetic sampling occurs when the velocity of air entering the sampling device is exactly equal to the velocity of air flowing inside the main pipeline. Although it may seem like a small detail, it is one of the most important factors for obtaining reliable particle measurements.<\/p>\n\n<div style=\"display:grid;grid-template-columns:1fr 1fr;gap:16px;margin:24px 0;\">\n  <div class=\"exair-content-block\">\n    <h3>\u26a0 Over-sampling<\/h3>\n    <p>If the inlet velocity to the sampler is <strong>higher<\/strong> than the main flow velocity, more particles than actually present are drawn in \u2014 especially large and heavy particles. Results appear <strong>falsely high<\/strong>.<\/p>\n  <\/div>\n  <div class=\"exair-content-block\">\n    <h3>\u26a0 Under-sampling<\/h3>\n    <p>If the inlet velocity is <strong>lower<\/strong>, heavier particles cannot enter the measurement system. The detected concentration is artificially reduced. Results appear <strong>falsely low<\/strong>.<\/p>\n  <\/div>\n<\/div>\n\n<p><strong>Without isokinetic conditions, even the best particle counter can deliver incorrect results.<\/strong><\/p>\n\n<h2>The Real Challenge in Industrial Plants<\/h2>\n<p>In practice, maintaining isokinetic sampling manually is extremely difficult because compressed air systems are constantly changing: pressure variations, flow changes, variable production demand, and fluctuations between the main line and points of use. These conditions continuously modify the flow velocity inside the pipeline, causing many audits to generate inconsistent or poorly repeatable results.<\/p>\n\n\n\n<div style=\"margin:24px 0;\">\n  <img decoding=\"async\" src=\"https:\/\/airtec.global\/wp-content\/uploads\/2026\/06\/SUTO-iTEC-S600-portable-compressed-air-purity-analyzer-for-quality-measurement2-min-1.jpg\" alt=\"SUTO iTEC S600 portable compressed air purity analyzer with isokinetic sampling device\" style=\"width:100%;max-width:600px;display:block;margin:0 auto;border-radius:8px;\" title=\"\">\n<\/div>\n\n\n\n<h2>The Solution: SUTO iTEC S600 with Isokinetic Sampling<\/h2>\n<p>To solve this problem, SUTO iTEC developed the S600 Portable Compressed Air Purity Analyzer together with a specialized isokinetic sampling device designed in accordance with ISO 8573-4.<\/p>\n\n<div style=\"display:grid;grid-template-columns:1fr 1fr;gap:16px;margin:24px 0;\">\n  <div class=\"exair-content-block\">\n    <h3>What does the S600 measure?<\/h3>\n    <ul style=\"list-style:none;padding:0;margin:0;\">\n      <li style=\"padding:6px 0 6px 24px;position:relative;border-bottom:0.5px solid #eee;\"><span style=\"position:absolute;left:0;color:#f5c518;font-weight:700;\">\u2713<\/span> Particles<\/li>\n      <li style=\"padding:6px 0 6px 24px;position:relative;border-bottom:0.5px solid #eee;\"><span style=\"position:absolute;left:0;color:#f5c518;font-weight:700;\">\u2713<\/span> Dew point<\/li>\n      <li style=\"padding:6px 0 6px 24px;position:relative;border-bottom:0.5px solid #eee;\"><span style=\"position:absolute;left:0;color:#f5c518;font-weight:700;\">\u2713<\/span> Oil vapor<\/li>\n      <li style=\"padding:6px 0 6px 24px;position:relative;border-bottom:0.5px solid #eee;\"><span style=\"position:absolute;left:0;color:#f5c518;font-weight:700;\">\u2713<\/span> Pressure<\/li>\n      <li style=\"padding:6px 0 6px 24px;position:relative;\"><span style=\"position:absolute;left:0;color:#f5c518;font-weight:700;\">\u2713<\/span> Temperature<\/li>\n    <\/ul>\n  <\/div>\n  <div class=\"exair-content-block\">\n    <h3>Integrated isokinetic device<\/h3>\n    <ul style=\"list-style:none;padding:0;margin:0;\">\n      <li style=\"padding:6px 0 6px 24px;position:relative;border-bottom:0.5px solid #eee;\"><span style=\"position:absolute;left:0;color:#f5c518;font-weight:700;\">\u2713<\/span> ISO 8573-4 sampling tube<\/li>\n      <li style=\"padding:6px 0 6px 24px;position:relative;border-bottom:0.5px solid #eee;\"><span style=\"position:absolute;left:0;color:#f5c518;font-weight:700;\">\u2713<\/span> Continuous flow monitoring<\/li>\n      <li style=\"padding:6px 0 6px 24px;position:relative;border-bottom:0.5px solid #eee;\"><span style=\"position:absolute;left:0;color:#f5c518;font-weight:700;\">\u2713<\/span> Needle valve adjustment<\/li>\n      <li style=\"padding:6px 0 6px 24px;position:relative;border-bottom:0.5px solid #eee;\"><span style=\"position:absolute;left:0;color:#f5c518;font-weight:700;\">\u2713<\/span> Real point-of-use simulation<\/li>\n      <li style=\"padding:6px 0 6px 24px;position:relative;\"><span style=\"position:absolute;left:0;color:#f5c518;font-weight:700;\">\u2713<\/span> Improved repeatability and precision<\/li>\n    <\/ul>\n  <\/div>\n<\/div>\n\n<h2>Key Advantages of the S600<\/h2>\n<div style=\"display:grid;grid-template-columns:1fr 1fr;gap:16px;margin:24px 0;\">\n  <div class=\"exair-content-block\">\n    <h3>1. All-in-one portable unit<\/h3>\n    <p>Reduces audit time, connections, and operational complexity. Significantly improves field efficiency.<\/p>\n  <\/div>\n  <div class=\"exair-content-block\">\n    <h3>2. Automatic PDF reports<\/h3>\n    <p>Ideal for ISO, FDA, QA audits, technical documentation, and internal validations.<\/p>\n  <\/div>\n  <div class=\"exair-content-block\">\n    <h3>3. Intuitive touchscreen<\/h3>\n    <p>Simplifies configuration, navigation, and guided measurements, reducing human error.<\/p>\n  <\/div>\n  <div class=\"exair-content-block\">\n    <h3>4. Integrated data logger<\/h3>\n    <p>Stores up to 100 million recorded values for full analysis and traceability.<\/p>\n  <\/div>\n<\/div>\n\n<h2>Industries Where This Is Critical<\/h2>\n<div style=\"display:grid;grid-template-columns:1fr 1fr;gap:16px;margin:24px 0;\">\n  <div class=\"exair-content-block\">\n    <h3>Pharmaceutical industry<\/h3>\n    <p>Compressed air may come into direct contact with products, sterile areas, filling systems, and cleanrooms. An incorrect measurement can compromise complete validations.<\/p>\n  <\/div>\n  <div class=\"exair-content-block\">\n    <h3>Food &#038; Beverage<\/h3>\n    <p>Compressed air is involved in packaging, pneumatic transport, PET lines, and indirect product contact. Contamination can affect quality and food safety.<\/p>\n  <\/div>\n  <div class=\"exair-content-block\">\n    <h3>Electronics<\/h3>\n    <p>Requires extremely clean environments where microscopic particles can damage sensitive components.<\/p>\n  <\/div>\n  <div class=\"exair-content-block\">\n    <h3>Hospitals &#038; Medical Devices<\/h3>\n    <p>Compressed air quality is critical for respiratory equipment, hospital systems, and medical manufacturing.<\/p>\n  <\/div>\n<\/div>\n\n<h2>Precision Starts Before the Sensor<\/h2>\n<p>The quality of a particle measurement depends not only on the equipment used \u2014 it depends on the sampling method. ISO 8573-4 clearly establishes the need for isokinetic conditions to guarantee representative and reliable results. With the <a href=\"https:\/\/airtec.global\/en\/product\/s600-portable-compressed-air-quality-analyzer\/\">SUTO iTEC S600 and its isokinetic sampling device<\/a>, industries can perform compressed air quality audits with greater precision, repeatability, and regulatory confidence.<\/p>\n\n\n\n<div style=\"margin:24px 0;\">\n  <img decoding=\"async\" src=\"https:\/\/airtec.global\/wp-content\/uploads\/2026\/06\/Avantor13-1-1-500x650-1.png\" alt=\"ISO 8573 compressed air quality audit with SUTO iTEC S600 analyzer in pharmaceutical plant\" style=\"width:100%;max-width:500px;display:block;margin:0 auto;border-radius:8px;\" title=\"\">\n<\/div>\n\n\n\n<div class=\"exair-footer-note\" style=\"margin-top:24px;\">\n  <p>Need to validate your compressed air quality? At Airtec we can help you with ISO 8573 audits, particle measurement, and SUTO iTEC solutions. Explore the <a href=\"https:\/\/airtec.global\/en\/product\/s600-portable-compressed-air-quality-analyzer\/\">SUTO iTEC S600<\/a>, request an <a href=\"https:\/\/airtec-servicios.com\/product\/auditoria-de-calidad-de-aire-comprimido-iso8573-1\/\" target=\"_blank\" rel=\"nofollow noopener\">ISO 8573-1 Quality Audit<\/a>, or visit the official <a href=\"https:\/\/www.suto-itec.com\/en\/products\/s600-compressed-air-purity-analyzer-portable-version-for-quality-measurement\/\" target=\"_blank\" rel=\"noopener\">SUTO iTEC website<\/a>.<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>SUTO iTEC \u00b7 S600 ISO 8573-4 and Isokinetic Sampling ISO 8573-4 isokinetic sampling is the critical factor that determines whether your compressed<\/p>","protected":false},"author":4,"featured_media":27595,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_coblocks_attr":"","_coblocks_dimensions":"","_coblocks_responsive_height":"","_coblocks_accordion_ie_support":"","footnotes":""},"categories":[373,326],"tags":[],"class_list":["post-27530","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-suto","category-sabias-que"],"_links":{"self":[{"href":"https:\/\/airtec.global\/en\/wp-json\/wp\/v2\/posts\/27530","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/airtec.global\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/airtec.global\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/airtec.global\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/airtec.global\/en\/wp-json\/wp\/v2\/comments?post=27530"}],"version-history":[{"count":3,"href":"https:\/\/airtec.global\/en\/wp-json\/wp\/v2\/posts\/27530\/revisions"}],"predecessor-version":[{"id":27596,"href":"https:\/\/airtec.global\/en\/wp-json\/wp\/v2\/posts\/27530\/revisions\/27596"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/airtec.global\/en\/wp-json\/wp\/v2\/media\/27595"}],"wp:attachment":[{"href":"https:\/\/airtec.global\/en\/wp-json\/wp\/v2\/media?parent=27530"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/airtec.global\/en\/wp-json\/wp\/v2\/categories?post=27530"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/airtec.global\/en\/wp-json\/wp\/v2\/tags?post=27530"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}