Cart

S230 / S231 – Dew Point Sensor for Harsh Environments

Accurate dew point measurement in potentially explosive atmospheres with ATEX and IECEx certification.


  • Dew point measurement from –100 … +20 °C Td (depending on model)
  • ATEX and IECEx certification for classified hazardous areas
  • High accuracy and stability across the entire measuring range
  • Advanced sensor technology (Polymer / Polymer + QCM)
  • 4…20 mA output + Modbus/RTU (RS-485) communication
  • Robust IP65 design for demanding industrial environments
  • Calculation of multiple humidity parameters
  • M8 connector and cable with open wire ends

Request A Quote.

Compare

Share this product

Description

5 Airtec Global

Safe and precise dew point monitoring in classified areas.


The S230 / S231 are designed for continuous and reliable dew point measurement in demanding industrial applications and potentially explosive atmospheres. Their robust construction and ATEX and IECEx certifications ensure safe operation in hazardous classified zones.
The S230 model features exclusive dual-sensor technology (Polymer + QCM), which automatically optimizes sensitivity to maintain high accuracy even at extremely low humidity levels. The S231 provides stable and reliable performance for applications down to –50 °C Td and at elevated pressures.
Both units are supplied ready for installation and can be easily integrated into control systems via 4–20 mA analog output or Modbus/RTU (RS-485) digital communication. Parameters can be conveniently configured using the service software, enabling fast and efficient commissioning.
Their long-term stability and fast response to humidity changes make them an ideal solution for protecting processes, equipment, and product quality in compressed air and industrial gas systems.

Advantages


ATEX and IECEx certification for safe operation in classified hazardous areas

Ultra-low dew point measurement down to –100 °C Td (S230)

Dual-sensor technology (Polymer + QCM) for enhanced reliability and accuracy

High long-term stability and fast response to humidity changes

Compact and robust design with IP65 protection

Easy integration via 4…20 mA output or Modbus RTU (RS-485)

Simple installation with M8 connector and cable with open wire ends


Applications


Desiccant and refrigerated dryers

Compressed air systems in classified hazardous areas

Industrial furnaces and thermal processes

Chemical and petrochemical plants

Industrial gas generation and treatment

Processes where moisture can affect quality or safety



6 Airtec Global

Videos


Technical Details


Pressure range:

  • S230: –0.1 … 1.6 MPa
  • S231: –0.1 … 35 MPa

Operating temperature: 0 … +50 °C

Power supply: 15 … 30 VDC

Typical consumption: 40 mA @ 24 VDC

Process connection: G 1/2” stainless steel

Housing material: High-strength industrial aluminum

  • Response time optimized for continuous monitoring
  • Compatible with measuring chambers and installation accessories
  • Configuration and diagnostics via service software
Accurate dew point measurement down to –100 °C Td for critical industrial processes.
Accurate dew point measurement down to –100 °C Td for critical industrial processes.

Downloads


Airtec Global

Select at least 2 products
to compare